Emergency and Exit Lighting Systems
Reliable Life-Safety Lighting Solutions for Code Compliance and Occupant Safety
High Voltage Services LLC installs, tests, and maintains emergency and exit lighting systems to ensure your facility stays compliant with safety codes and prepared for unexpected power outages. We help protect occupants and meet building requirements by delivering dependable lighting for safe egress and emergency visibility.
Whether it’s a new construction project or an upgrade to outdated systems, our team designs and installs compliant, energy-efficient lighting solutions that meet all NFPA and building code standards.
What Are Emergency and Exit Lighting Systems?
These systems are essential life-safety features designed to operate during power failures, guiding occupants safely out of a building during emergencies. They typically include:
- Exit signs (illuminated or self-luminous)
- Battery backup lighting (wall-mounted or ceiling-mounted)
- Egress pathway lighting
- Remote heads and bug-eye fixtures
- Self-diagnostic testing features
- Central inverter systems for large buildings
We install both standalone systems and integrated emergency lighting tied into your building’s electrical or generator backup systems.
Why Emergency and Exit Lighting Matters
1. Code Compliance: Exit and emergency lighting is required by OSHA, the National Fire Protection Association (NFPA 101), and the International Building Code (IBC). Failure to comply can result in failed inspections or legal liability.
2. Occupant Safety: During a power outage, fire, or evacuation event, visibility is critical. These systems help guide people to safety, reducing panic and injury.
3. Legal Liability Protection: Failing to provide properly functioning emergency lighting may expose building owners and managers to significant liability in the event of an incident.
4. Insurance Requirements: Most commercial insurance policies require that emergency systems be functional and tested regularly as part of their loss prevention standards.
Services We Offer
High Voltage Services LLC offers full-service support for emergency and exit lighting, including:
New Installations
- We install emergency lighting in all types of facilities. Our team designs system layouts based on egress paths, occupancy load, and applicable fire and building codes.
Fixture Upgrades
- Replace outdated or non-functional fixtures with modern, energy-efficient LED models. We offer fixtures with built-in battery backup and self-test functionality.
Testing & Inspections
- We conduct scheduled inspections and functionality tests to ensure your emergency systems meet NFPA 101 Life Safety Code requirements.
Maintenance & Repairs
- Need batteries, bulbs, or circuits replaced? We service and maintain emergency fixtures to keep everything operational year-round.
Central Inverter System Integration
- For large buildings or campuses, we install inverter-based systems that provide centralized power to emergency lighting during outages.
What’s Included in Our Maintenance Contracts?
You’ll also receive priority service and discounted rates on repairs, upgrades, and emergency calls as part of any contract.
Compatible with All Facility Types
We install and maintain emergency lighting systems in:
- Office buildings
- Retail spaces and shopping malls
- Restaurants and hotels
- Healthcare facilities and clinics
- Warehouses and industrial plants
- Schools, universities, and dormitories
- Government and municipal buildings
Theaters, churches, and entertainment venues
Code Requirements We Help You Meet
We ensure all installations and services comply with relevant codes and standards:
- NFPA 101: Life Safety Code
- NEC Article 700 and 701
- IBC/IFC Requirements
- OSHA 1910.37 (Exit routes and emergency lighting)
- ADA visibility and mounting height requirements
- Local jurisdiction and fire marshal specifications
Inspection and Testing Includes:
- 30-second functional test (monthly)
- 90-minute full-load test (annually)
- Battery condition check
- Lamp and ballast functionality
- Photometric coverage verification
- Sign visibility and illumination
- Self-test diagnostics (if applicable)
- Logbook and report preparation
Ask about our preventive maintenance contracts to automate testing and documentation.
Integrated Lighting Solutions
We can integrate your emergency lighting into:
- Building fire alarm systems
- Backup generators
- Smart building controls
- Central battery banks or inverter systems
- Exit and directional signage networks
Our integrated systems are perfect for multi-tenant buildings, warehouses, educational campuses, and large retail environments.
Product Types We Install
- LED exit signs with or without arrows
- Edge-lit exit signage for modern aesthetics
- Combo units (exit sign + emergency lights)
- Remote emergency light heads
- Thermoplastic and steel housings
- Wet-location emergency lighting
- Recessed and architectural models
- Self-testing and self-diagnostic units
- Photoluminescent (glow-in-the-dark) exit signs
All fixtures meet UL 924 standards for emergency lighting.
Common Questions
How often should emergency lighting be tested?
Monthly functional tests (30 seconds) and an annual 90-minute test are required by code. We provide full documentation for both.
Do emergency lights need to be on their own circuit?
Yes, most codes require emergency fixtures to be on dedicated circuits or lighting branches with automatic transfer to backup power.
Can emergency lights run off a generator?
Yes. In large facilities, they’re often connected to generator backup systems or central inverter units. We design the system based on your power setup.
What happens if one exit sign is out?
Even one failed fixture can result in a code violation or failed inspection. We recommend regular inspections and prompt repair.
Why Professional Design Matters
Improper placement or inadequate illumination can lead to compliance issues or unsafe evacuation conditions. We use photometric planning to ensure your emergency lighting meets:
- Visibility at every exit point
- Illumination along the full egress path
- Mounting height and angle requirements
- Power duration and brightness output minimums
Service Area – Based in Pompano Beach, Serving Nearby Cities
- Pompano Beach (Our headquarters)
- Lighthouse Point
- Deerfield Beach
- Coconut Creek
- Margate
- Coral Springs
- Parkland
- North Lauderdale
- Tamarac
- Lauderdale-by-the-Sea
- Oakland Park
- Wilton Manors
- Fort Lauderdale
- Lauderhill
- Sunrise
- Boynton Beach (Southern Area)
- Boca Raton
- Davie
- Dania Beach
- Plantation
Why Choose High Voltage Services LLC?
- Licensed, insured, and code-certified
- Familiar with all major fixture brands
- Experienced in retrofits and new installs
- Custom layouts and CAD support
- Emergency response for lighting failures
Maintenance plans available for ongoing support